Re: [PATCH 2/5] tsc2007: Add max_rt module parameter.

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi Thierry,

On Mon, May 16, 2011 at 10:33:00AM +0200, Thierry Reding wrote:
> Finger touch events or very quick stylus events on low-quality panels
> can cause the tsc2007 to read bogus values. Looking at oscilloscope
> snapshots, this seems to be caused by the touch event disappearing
> during the measurements. These bogus values result in misclicks, where
> the X and Y values deviate from the real position.
> 
> Most of these misclicks can be filtered out by setting a low enough
> threshold for the maximum resistance (which is loosely the inverse of
> the pressure) allowed to consider a set of values valid. Since this
> behaviour is largely dependent on the type and quality of the panel,
> this commit introduces the max_rt parameter. The default value is kept
> at MAX_12BIT.

I expect that the values, once selected, will not be changed for a given
panel, so why don't we pass max_rt (and poll_delay and poll_interval) vi
platform (board) data instead of being module parameters?

Thanks.

-- 
Dmitry
--