Re: ads7846: clean up, fix pressure reporting

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Pavel Machek wrote:
> Fix pressure reporting, and clean up debug prints.

Thanks.

I see much bigger problem with both the old driver and the new ads7846
driver (2.6.30): They are very noisy on my spitz. When you tap to one
place, keep stylus pressed and just read values, you get 20-200 pixels
long pointer motion trip each second.

According to Cyril Hrubiš, it is caused by the electrical noise that
originates in the LCD display. The driver needs to read data
synchronously with the LCD refresh. He already made the fix for collie
several years ago.

The pointer test application in the PROM diagnostic utility does not
seem to exhibit any noise.


________________________________________________________________________
Stanislav Brabec
http://www.penguin.cz/~utx/zaurus

--
To unsubscribe from this list: send the line "unsubscribe linux-input" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html

[Index of Archives]     [Linux Media Devel]     [Linux USB Devel]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Kernel]     [Linux SCSI]     [Linux Wireless Networking]     [Linux Omap]

  Powered by Linux