From: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx> To make code more readable, use a structure to express the channel layout and ensure the timestamp is 8 byte aligned. Found during an audit of all calls of this function. Fixes: d3bf60450d47 ("iio: hx711: add triggered buffer support") Signed-off-by: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx> Cc: Andreas Klinger <ak@xxxxxxxxxxxxx> --- drivers/iio/adc/hx711.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/drivers/iio/adc/hx711.c b/drivers/iio/adc/hx711.c index 6a173531d355..f7ee856a6b8b 100644 --- a/drivers/iio/adc/hx711.c +++ b/drivers/iio/adc/hx711.c @@ -86,9 +86,9 @@ struct hx711_data { struct mutex lock; /* * triggered buffer - * 2x32-bit channel + 64-bit timestamp + * 2x32-bit channel + 64-bit naturally aligned timestamp */ - u32 buffer[4]; + u32 buffer[4] __aligned(8); /* * delay after a rising edge on SCK until the data is ready DOUT * this is dependent on the hx711 where the datasheet tells a -- 2.31.1