Fix bug in sampling function hx711_cycle() when interrupt occures while PD_SCK is high. If PD_SCK is high for at least 60 us power down mode of the sensor is entered which in turn leads to a wrong measurement. Move query of DOUT at the latest point of time which is at the end of PD_SCK low period. Signed-off-by: Andreas Klinger <ak@xxxxxxxxxxxxx> --- drivers/iio/adc/hx711.c | 9 +++++---- 1 file changed, 5 insertions(+), 4 deletions(-) diff --git a/drivers/iio/adc/hx711.c b/drivers/iio/adc/hx711.c index 88c7fe15003b..0678964dbd21 100644 --- a/drivers/iio/adc/hx711.c +++ b/drivers/iio/adc/hx711.c @@ -101,13 +101,14 @@ struct hx711_data { static int hx711_cycle(struct hx711_data *hx711_data) { int val; + unsigned long flags; /* * if preempted for more then 60us while PD_SCK is high: * hx711 is going in reset * ==> measuring is false */ - preempt_disable(); + local_irq_save(flags); gpiod_set_value(hx711_data->gpiod_pd_sck, 1); /* @@ -117,7 +118,6 @@ static int hx711_cycle(struct hx711_data *hx711_data) */ ndelay(hx711_data->data_ready_delay_ns); - val = gpiod_get_value(hx711_data->gpiod_dout); /* * here we are not waiting for 0.2 us as suggested by the datasheet, * because the oscilloscope showed in a test scenario @@ -125,7 +125,7 @@ static int hx711_cycle(struct hx711_data *hx711_data) * and 0.56 us for PD_SCK low on TI Sitara with 800 MHz */ gpiod_set_value(hx711_data->gpiod_pd_sck, 0); - preempt_enable(); + local_irq_restore(flags); /* * make it a square wave for addressing cases with capacitance on @@ -133,7 +133,8 @@ static int hx711_cycle(struct hx711_data *hx711_data) */ ndelay(hx711_data->data_ready_delay_ns); - return val; + /* sample as late as possible */ + return gpiod_get_value(hx711_data->gpiod_dout); } static int hx711_read(struct hx711_data *hx711_data) -- 2.13.3