There are several options in the device tree documentation that are no longer relevant for the current in-kernel bmp280 driver so this patch removes them. Signed-off-by: Brian Masney <masneyb@xxxxxxxxxxxxx> --- Documentation/devicetree/bindings/iio/pressure/bmp085.txt | 7 ------- 1 file changed, 7 deletions(-) diff --git a/Documentation/devicetree/bindings/iio/pressure/bmp085.txt b/Documentation/devicetree/bindings/iio/pressure/bmp085.txt index c7198a03c906..abcab02504fb 100644 --- a/Documentation/devicetree/bindings/iio/pressure/bmp085.txt +++ b/Documentation/devicetree/bindings/iio/pressure/bmp085.txt @@ -8,10 +8,6 @@ Required properties: "bosch,bme280" Optional properties: -- chip-id: configurable chip id for non-default chip revisions -- temp-measurement-period: temperature measurement period (milliseconds) -- default-oversampling: default oversampling value to be used at startup, - value range is 0-3 with rising sensitivity. - interrupt-parent: should be the phandle for the interrupt controller - interrupts: interrupt mapping for IRQ - reset-gpios: a GPIO line handling reset of the sensor: as the line is @@ -24,9 +20,6 @@ Example: pressure@77 { compatible = "bosch,bmp085"; reg = <0x77>; - chip-id = <10>; - temp-measurement-period = <100>; - default-oversampling = <2>; interrupt-parent = <&gpio0>; interrupts = <25 IRQ_TYPE_EDGE_RISING>; reset-gpios = <&gpio0 26 GPIO_ACTIVE_LOW>; -- 2.17.1 -- To unsubscribe from this list: send the line "unsubscribe linux-iio" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html