On Mon, Apr 10, 2017 at 7:00 PM, Andreas Klinger <ak@xxxxxxxxxxxxx> wrote: > While calculating the compensation of the humidity there are negative values > interpreted as unsigned because of unsigned variables used. These values as > well as the constants need to be casted to signed as indicated by the > documentation of the sensor. > > Changes in v2: > - cast also constants to signed; otherwise calculation is not correct > > I removed the Acked-By of Linus Walleij because of another change in the > calculation. Don't know how it should be treated. Acked-by: Linus Walleij <linus.walleij@xxxxxxxxxx> You guys do an awesome job at maintaining the sensor code, thanks. Yours, Linus Walleij -- To unsubscribe from this list: send the line "unsubscribe linux-iio" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html