On 29 June 2016 at 14:08, Linus Walleij <linus.walleij@xxxxxxxxxx> wrote: > The code was not powering the magnetometer down properly at > remove(): just cutting the regulators without first setting the > device in power off mode. Fix this. > > Cc: Ulf Hansson <ulf.hansson@xxxxxxxxxx> > Signed-off-by: Linus Walleij <linus.walleij@xxxxxxxxxx> Reviewed-by: Ulf Hansson <ulf.hansson@xxxxxxxxxx> Kind regards Uffe > --- > ChangeLog v2->v3: > - Rebase > ChangeLog v1->v2: > - New patch in the series after Ulf's review comment that this > should be separate. > --- > drivers/iio/magnetometer/ak8975.c | 1 + > 1 file changed, 1 insertion(+) > > diff --git a/drivers/iio/magnetometer/ak8975.c b/drivers/iio/magnetometer/ak8975.c > index c67cf3a6128d..43dc1c74be9e 100644 > --- a/drivers/iio/magnetometer/ak8975.c > +++ b/drivers/iio/magnetometer/ak8975.c > @@ -990,6 +990,7 @@ static int ak8975_remove(struct i2c_client *client) > > iio_device_unregister(indio_dev); > iio_triggered_buffer_cleanup(indio_dev); > + ak8975_set_mode(data, POWER_DOWN); > ak8975_power_off(data); > > return 0; > -- > 2.4.11 > -- To unsubscribe from this list: send the line "unsubscribe linux-iio" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html