On Wed, Aug 12, 2015 at 12:12:36PM +0200, Markus Pargmann wrote: > + /* > + * There are busses that do not have a read function as it is optional. > + * Use their reg_read function instead if the requested number of bytes > + * is correct. > + */ > + if (!map->bus->read) { > + /* > + * bus_reg_read() does not support reading values that are not > + * exactly the size of format.val_bytes > + */ > + if (val_len != map->format.val_bytes) > + return -EINVAL; > + return _regmap_bus_reg_read(map, reg, val); > + } No, this makes no sense - if the device doesn't have a read operation then it doesn't support a raw data stream and hence can't support raw access sensibly. Callers that want to access a lot of registers at once without knowing what the wire format for the device is should be using the bulk or multi interfaces.