Re: [PATCH 3/3] iio: magnetometer: mmc35240: fix SET/RESET sequence

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 16/07/15 14:30, Daniel Baluta wrote:
> On Tue, Jul 14, 2015 at 11:04 PM, Jonathan Cameron <jic23@xxxxxxxxxx> wrote:
>>
>>
>> On 14 July 2015 15:56:54 BST, Daniel Baluta <daniel.baluta@xxxxxxxxx> wrote:
>>> From: Viorel Suman <viorel.suman@xxxxxxxxx>
>>>
>>> The RESET operation invoked in the last instance will align
>>> in the natural way all 3 axis and the chip top view.
>> What is the result of the bug?
>> Just trying to assess urgency of the patch!
> 
> Compass app shows North and South switched. This can be corrected
> from mounting matrix though.
> 
Applied.
> Daniel.
> --
> To unsubscribe from this list: send the line "unsubscribe linux-iio" in
> the body of a message to majordomo@xxxxxxxxxxxxxxx
> More majordomo info at  http://vger.kernel.org/majordomo-info.html
> 

--
To unsubscribe from this list: send the line "unsubscribe linux-iio" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html