On Tue, Jun 16, 2015 at 11:36 PM, Peter Meerwald <pmeerw@xxxxxxxxxx> wrote: > Signed-off-by: Peter Meerwald <pmeerw@xxxxxxxxxx> Oh, didn't see that :) Reviewed-by: Daniel Baluta <daniel.baluta@xxxxxxxxx> > --- > Documentation/ABI/testing/sysfs-bus-iio | 2 +- > 1 file changed, 1 insertion(+), 1 deletion(-) > > diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio > index 3befcb1..7d909a4 100644 > --- a/Documentation/ABI/testing/sysfs-bus-iio > +++ b/Documentation/ABI/testing/sysfs-bus-iio > @@ -1162,7 +1162,7 @@ KernelVersion: 3.4 > Contact: linux-iio@xxxxxxxxxxxxxxx > Description: > Proximity measurement indicating that some > - object is near the sensor, usually be observing > + object is near the sensor, usually by observing > reflectivity of infrared or ultrasound emitted. > Often these sensors are unit less and as such conversion > to SI units is not possible. Where it is, the units should > -- -- To unsubscribe from this list: send the line "unsubscribe linux-iio" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html