[PATCH 4/6] iio: magnetometer: mmc35240: Use a smaller sleep value

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



According to datasheet, Page 8, minimum wait time to complete
measurement is 10ms. Adjusting this value will increase the
userspace polling rate.

Fixes: abeb6b1e7b ("iio: magnetometer: Add support for MEMSIC MMC35240")
Signed-off-by: Daniel Baluta <daniel.baluta@xxxxxxxxx>
---
 drivers/iio/magnetometer/mmc35240.c | 3 ++-
 1 file changed, 2 insertions(+), 1 deletion(-)

diff --git a/drivers/iio/magnetometer/mmc35240.c b/drivers/iio/magnetometer/mmc35240.c
index c520117..35eb6fd 100644
--- a/drivers/iio/magnetometer/mmc35240.c
+++ b/drivers/iio/magnetometer/mmc35240.c
@@ -219,7 +219,8 @@ static int mmc35240_take_measurement(struct mmc35240_data *data)
 			return ret;
 		if (reg_status & MMC35240_STATUS_MEAS_DONE_BIT)
 			break;
-		msleep(20);
+		/* minimum wait time to complete measurement is 10 ms */
+		usleep_range(10000, 11000);
 	}
 
 	if (tries < 0) {
-- 
1.9.1

--
To unsubscribe from this list: send the line "unsubscribe linux-iio" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html