On 08/04/15 16:30, Vlad Dogaru wrote: > On Wed, Apr 08, 2015 at 06:26:12PM +0300, Irina Tirdea wrote: >> Temperature reads on bmp280 device always return 0, >> due to a missing step in the compensation formula >> (data->tfine is never initialized). >> >> Initialize data->tfine value so we get correct >> temperature and pressure values. >> >> Signed-off-by: Irina Tirdea <irina.tirdea@xxxxxxxxx> > > Reviewed-by: Vlad Dogaru <vlad.dogaru@xxxxxxxxx> > > Nice catch, this must have been lost during a refactoring. > > Thanks, > Vlad > Thanks, Applied to fixes-togreg which is now based on staging-next which gives you an idea of when this will go to Greg now! -- To unsubscribe from this list: send the line "unsubscribe linux-iio" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html