On Sun, Jan 18, 2015 at 11:49:27AM +0100, Sebastian Reichel wrote: > Hi, > > On Wed, Jan 07, 2015 at 01:26:55PM -0800, Todd E Brandt wrote: > > X-Power AXP288 PMIC Fuel Gauge Driver > > > > new power_supply driver at driver/power > > interfaces with the axp20x mfd driver as a cell > > provides battery info and monitors for changes > > generates alerts on temperature and capacity issues > > > > [...] > > > > +static int fuel_gauge_battery_health(struct axp288_fg_info *info) > > +{ > > + int temp, vocv; > > + int ret, health = POWER_SUPPLY_HEALTH_UNKNOWN; > > + > > + ret = fuel_gauge_get_btemp(info, &temp); > > + if (ret < 0) > > + goto health_read_fail; > > + > > + ret = fuel_gauge_get_vocv(info, &vocv); > > + if (ret < 0) > > + goto health_read_fail; > > + > > + if (vocv > info->pdata->max_volt) > > + health = POWER_SUPPLY_HEALTH_OVERVOLTAGE; > > + else if (temp > info->pdata->max_temp || > > + temp < info->pdata->min_temp) > > + health = POWER_SUPPLY_HEALTH_OVERHEAT; > > if (temp < info->pdata->min_temp) > health = POWER_SUPPLY_HEALTH_COLD; Will add in v2, thanks. > > > + else if (vocv < info->pdata->min_volt) > > + health = POWER_SUPPLY_HEALTH_DEAD; > > + else > > + health = POWER_SUPPLY_HEALTH_GOOD; > > + > > +health_read_fail: > > + return health; > > +} > > > > [...] > > > > +static int axp288_fuel_gauge_remove(struct platform_device *pdev) > > +{ > > + return 0; > > +} > > You can drop this function if nothing needs to be cleaned, but > that's not the case, so where is the cleanup code? You're right, I believe it needs: cancel_delayed_work_sync(&info->status_monitor); power_supply_unregister(&info->bat); will add in v2, thanks > > > [...] > > -- Sebastian -- To unsubscribe from this list: send the line "unsubscribe linux-iio" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html