[PATCH v2 5/8] ata: libata-scsi: fix timeout type in ata_scsi_park_store()

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



ata_scsi_park_store() passes its 'long input' variable (if it's >= 0) to
ata_deadline() that now takes 'unsigned int' -- eliminate unneeded implicit
cast...

Signed-off-by: Sergey Shtylyov <s.shtylyov@xxxxxx>
---
Changes in version 2:
- refreshed the patch.

 drivers/ata/libata-scsi.c | 4 ++--
 1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/drivers/ata/libata-scsi.c b/drivers/ata/libata-scsi.c
index 370d18aca71e..f39d603f05bc 100644
--- a/drivers/ata/libata-scsi.c
+++ b/drivers/ata/libata-scsi.c
@@ -135,11 +135,11 @@ static ssize_t ata_scsi_park_store(struct device *device,
 	struct scsi_device *sdev = to_scsi_device(device);
 	struct ata_port *ap;
 	struct ata_device *dev;
-	long int input;
+	int input;
 	unsigned long flags;
 	int rc;
 
-	rc = kstrtol(buf, 10, &input);
+	rc = kstrtoint(buf, 10, &input);
 	if (rc)
 		return rc;
 	if (input < -2)
-- 
2.26.3