Hello! On 12/19/2016 4:17 AM, Damien Le Moal wrote:
For an ATA device supporting the sense data reporting feature set, a failed command will trigger the execution of ata_eh_request_sense if the result task file of the failed command has the ATA_SENSE bit set (sense data available bit). ata_eh_request_sense executes the REQUEST SENSE DATA EXT command to retrieve the sense data of the failed command. On success of REQUEST SENSE DATA EXT, the ATA_SENSE bit will NOT be set (the command succeeded) but ata_eh_request_sense nevertheless tests the availability of sense data by testing that bit presence in the result tf of the REQUEST SENSE DATA EXT command. This leads to a falsy assume that request sense data failed and to the
False assumption?
warning message: atax.xx: request sense failed stat 50 emask 0 Upon success of REQUEST SENSE DATA EXT, set the ATA_SENSE bit in the result task file command so that sense data can be returned by ata_eh_request_sense. Signed-off-by: Damien Le Moal <damien.lemoal@xxxxxxx>
[...] MBR, Sergei -- To unsubscribe from this list: send the line "unsubscribe linux-ide" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html