Hello, On Wed, May 04, 2011 at 04:17:27PM +0800, shaohua.li@xxxxxxxxx wrote: > In some drives, flush requests are non-queueable. When flush request is running, > normal read/write requests can't run. If block layer dispatches such request, > driver can't handle it and requeue it. > Tejun suggested we can hold the queue when flush is running. This can avoid > unnecessary requeue. > Also this can improve performance. Say we have requests f1, w1, f2 (f is flush > request, and w is write request). When f1 is running, queue will be hold, so w1 > will not be added to queue list. Just after f1 is finished, f2 will be > dispatched. Since f1 already flushs cache out, f2 can be finished very quickly. > In my test, the queue holding completely solves a regression introduced by > commit 53d63e6b0dfb9588, which is about 20% regression running a sysbench fileio > workload. > > Signed-off-by: Shaohua Li <shaohua.li@xxxxxxxxx> It looks good to me now, but some nitpicks. > Index: linux/block/blk-flush.c > =================================================================== > --- linux.orig/block/blk-flush.c 2011-05-04 14:20:33.000000000 +0800 > +++ linux/block/blk-flush.c 2011-05-04 15:23:50.000000000 +0800 > @@ -199,6 +199,9 @@ static void flush_end_io(struct request > > BUG_ON(q->flush_pending_idx == q->flush_running_idx); > > + queued |= q->flush_queue_delayed; > + q->flush_queue_delayed = 0; > + > /* account completion of the flush request */ > q->flush_running_idx ^= 1; > elv_completed_request(q, flush_rq); Can you please do if (queued || q->flush_queue_delayed) instead of setting queued? And please also update the comment above the if statement so that it explains the flush_queue_delayed case too. > Index: linux/block/blk.h > =================================================================== > --- linux.orig/block/blk.h 2011-05-04 14:20:33.000000000 +0800 > +++ linux/block/blk.h 2011-05-04 16:09:42.000000000 +0800 > @@ -61,7 +61,17 @@ static inline struct request *__elv_next > rq = list_entry_rq(q->queue_head.next); > return rq; > } > - > + /* > + * Flush request is running and flush request isn't queeueable > + * in the drive, we can hold the queue till flush request is > + * finished. Even we don't do this, driver can't dispatch next > + * requests and will requeue them. > + */ Please explain the f1, w1, f2 case here as that's the biggest reason this optimization is implemented and also explain the use of flush_queue_delayed (just explain briefly and refer to flush_end_io()). Thank you. -- tejun -- To unsubscribe from this list: send the line "unsubscribe linux-ide" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html