On 10/09/2007, Tejun Heo <htejun@xxxxxxxxx> wrote: > Michal Suchanek wrote: > > Hello > > > > (please CC me when replying) > > > > On 09/09/2007, Joris <joris@xxxxx> wrote: > >> Hi, > >> > >> Just a note to let you know you're not alone. > >> I have the same problem, and someone else reported something simelar. > >> > >> What sata controller are you using? > > > > The via onboard controller on the via chipset board and the Intel ICH7 > > integrated controller with this board. Looks like it is the drive and > > the used controller does not make any difference. > > > > 00:1f.2 IDE interface: Intel Corporation 82801GB/GR/GH (ICH7 Family) > > Serial ATA Storage Controller IDE (rev 01) > > What does 'smartctl -a /dev/sda' say? > Attaching output. Thanks Michal
smartctl version 5.37 [i686-pc-linux-gnu] Copyright (C) 2002-6 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Model Family: Maxtor DiamondMax 10 family (ATA/133 and SATA/150) Device Model: Maxtor 6L200M0 Firmware Version: BANC1E00 User Capacity: 203,928,109,056 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 7 ATA Standard is: ATA/ATAPI-7 T13 1532D revision 0 Local Time is: Mon Sep 10 16:03:42 2007 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled Warning! SMART Attribute Thresholds Structure error: invalid SMART checksum. === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x80) Offline data collection activity was never started. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (1562) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 81) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 3 Spin_Up_Time 0x0027 207 207 063 Pre-fail Always - 18457 4 Start_Stop_Count 0x0032 253 253 000 Old_age Always - 348 5 Reallocated_Sector_Ct 0x0033 253 253 063 Pre-fail Always - 2 6 Read_Channel_Margin 0x0001 253 253 100 Pre-fail Offline - 0 7 Seek_Error_Rate 0x000a 253 252 000 Old_age Always - 0 8 Seek_Time_Performance 0x0027 249 239 187 Pre-fail Always - 51048 9 Power_On_Minutes 0x0032 249 249 000 Old_age Always - 486h+06m 10 Spin_Retry_Count 0x002b 253 252 157 Pre-fail Always - 0 11 Calibration_Retry_Count 0x002b 253 252 223 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 252 252 000 Old_age Always - 771 192 Power-Off_Retract_Count 0x0032 253 253 000 Old_age Always - 0 193 Load_Cycle_Count 0x0032 253 253 000 Old_age Always - 0 194 Temperature_Celsius 0x0032 030 253 000 Old_age Always - 28 195 Hardware_ECC_Recovered 0x000a 253 252 000 Old_age Always - 3399 196 Reallocated_Event_Count 0x0008 253 253 000 Old_age Offline - 0 197 Current_Pending_Sector 0x0008 253 253 000 Old_age Offline - 0 198 Offline_Uncorrectable 0x0008 253 253 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0008 199 199 000 Old_age Offline - 0 200 Multi_Zone_Error_Rate 0x000a 253 252 000 Old_age Always - 0 201 Soft_Read_Error_Rate 0x000a 253 252 000 Old_age Always - 0 202 TA_Increase_Count 0x000a 253 252 000 Old_age Always - 0 203 Run_Out_Cancel 0x000b 253 252 180 Pre-fail Always - 0 204 Shock_Count_Write_Opern 0x000a 253 252 000 Old_age Always - 0 205 Shock_Rate_Write_Opern 0x000a 253 252 000 Old_age Always - 0 207 Spin_High_Current 0x002a 253 252 000 Old_age Always - 0 208 Spin_Buzz 0x002a 253 252 000 Old_age Always - 0 209 Offline_Seek_Performnce 0x0024 239 239 000 Old_age Offline - 172 210 Unknown_Attribute 0x0032 253 252 000 Old_age Always - 0 211 Unknown_Attribute 0x0032 253 252 000 Old_age Always - 0 212 Unknown_Attribute 0x0032 253 247 000 Old_age Always - 0 Warning! SMART ATA Error Log Structure error: invalid SMART checksum. SMART Error Log Version: 1 ATA Error Count: 2 CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 2 occurred at disk power-on lifetime: 1445 hours (60 days + 5 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 00 00 00 00 00 a0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- ec 00 00 00 00 00 a0 00 18:11:16.222 IDENTIFY DEVICE 25 00 00 61 45 21 e0 00 18:11:10.072 READ DMA EXT 25 00 80 e1 43 21 e0 00 18:11:10.069 READ DMA EXT 25 00 88 59 42 21 e0 00 18:11:10.066 READ DMA EXT 25 00 00 59 40 21 e0 00 18:11:10.062 READ DMA EXT Error 1 occurred at disk power-on lifetime: 1074 hours (44 days + 18 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 00 00 08 95 54 53 a0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- ec 00 08 95 54 53 a0 00 00:00:40.081 IDENTIFY DEVICE c8 00 08 94 54 53 e1 00 00:00:33.998 READ DMA c8 00 08 8c 54 53 e1 00 00:00:33.998 READ DMA c8 00 08 84 54 53 e1 00 00:00:33.998 READ DMA c8 00 08 7c 54 53 e1 00 00:00:33.998 READ DMA Error 0 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 00 00 00 00 00 00 00 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 00 3b 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.