[PATCH] libata: PHY reset requires writing 0x4 to SControl

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi,

Reading the Intel VSC and AHCI it seems like writing 0x302 is incorrect.
The only valid values are 4, 1 and 0.  Writing 4 disables the
PHY.

Signed-off-by: Martin Hicks <mort@xxxxxxxx>

---

 drivers/scsi/libata-core.c |    2 +-
 1 files changed, 1 insertions(+), 1 deletions(-)

99377743755ef015100ab52fd79ee950a783141b
diff --git a/drivers/scsi/libata-core.c b/drivers/scsi/libata-core.c
index 6c66877..577fbcc 100644
--- a/drivers/scsi/libata-core.c
+++ b/drivers/scsi/libata-core.c
@@ -2705,7 +2705,7 @@ int sata_std_hardreset(struct ata_port *
 		if ((rc = sata_scr_read(ap, SCR_CONTROL, &scontrol)))
 			return rc;
 
-		scontrol = (scontrol & 0x0f0) | 0x302;
+		scontrol = (scontrol & 0x0f0) | 0x304;
 
 		if ((rc = sata_scr_write(ap, SCR_CONTROL, scontrol)))
 			return rc;
-- 
1.3.2

-