Meson A1 temperature sensor has dedicated power domain so bind it to the device node. Signed-off-by: George Stark <gnstark@xxxxxxxxxxxxxxxxx> Reviewed-by: Neil Armstrong <neil.armstrong@xxxxxxxxxx> --- arch/arm64/boot/dts/amlogic/meson-a1.dtsi | 1 + 1 file changed, 1 insertion(+) diff --git a/arch/arm64/boot/dts/amlogic/meson-a1.dtsi b/arch/arm64/boot/dts/amlogic/meson-a1.dtsi index dd5695963caa..86d77f51c25c 100644 --- a/arch/arm64/boot/dts/amlogic/meson-a1.dtsi +++ b/arch/arm64/boot/dts/amlogic/meson-a1.dtsi @@ -919,6 +919,7 @@ cpu_temp: temperature-sensor@4c00 { assigned-clock-rates = <500000>; #thermal-sensor-cells = <0>; amlogic,ao-secure = <&sec_AO>; + power-domains = <&pwrc PWRC_I2C_ID>; }; hwrng: rng@5118 { -- 2.25.1