On Thu, 21 Mar 2024 16:21:42 +0200, Radu Sabau wrote: > Add dt-bindings for adp1050 digital controller for isolated power supply > with pmbus interface voltage, current and temperature monitor. > > Signed-off-by: Radu Sabau <radu.sabau@xxxxxxxxxx> > --- > v4: > *Fix typo in schema link causing warnings at build. > v3: > *Remove extra line before '$id'. > *Remove 'address-cells' and 'size-cells' from adp1050 node. > *Rename adp1050 node to generic name. > *Fix typo from 'adress-cells' to 'address-cells' causing errors in the > dt-bindings build. > v2: > *Fix identation for example. > *Remove 'adi,vin-scale-monitor' and 'iin-scale-monitor' since they are not used > anymore. > *Fix typo for 'compatbile' to 'compatible'. > *Add blank line under datasheet link. > --- > .../bindings/hwmon/pmbus/adi,adp1050.yaml | 49 +++++++++++++++++++ > MAINTAINERS | 7 +++ > 2 files changed, 56 insertions(+) > create mode 100644 Documentation/devicetree/bindings/hwmon/pmbus/adi,adp1050.yaml > Reviewed-by: Rob Herring <robh@xxxxxxxxxx>