On Sat, Nov 27, 2021 at 09:42:14PM +0200, Aaro Koskinen wrote: > CBUS transfers have always been atomic, but after commit 63b96983a5dd > ("i2c: core: introduce callbacks for atomic transfers") we started to see > warnings during e.g. poweroff as the atomic callback is not explicitly set. > Fix that. > > Fixes the following WARNING seen during Nokia N810 power down: > > [ 786.570617] reboot: Power down Applied to for-current, thanks!