In a typical read transfer, start completion flag is being set after read finishes (notice ipd bit 4 being set): trasnfer poll=0 i2c start rk3x-i2c fdd40000.i2c: IRQ: state 1, ipd: 10 i2c read rk3x-i2c fdd40000.i2c: IRQ: state 2, ipd: 1b i2c stop rk3x-i2c fdd40000.i2c: IRQ: state 4, ipd: 33 This causes I2C transfer being aborted in polled mode from a stop completion handler: trasnfer poll=1 i2c start rk3x-i2c fdd40000.i2c: IRQ: state 1, ipd: 10 i2c read rk3x-i2c fdd40000.i2c: IRQ: state 2, ipd: 0 rk3x-i2c fdd40000.i2c: IRQ: state 2, ipd: 1b i2c stop rk3x-i2c fdd40000.i2c: IRQ: state 4, ipd: 13 i2c stop rk3x-i2c fdd40000.i2c: unexpected irq in STOP: 0x10 Clearing the START flag after read fixes the issue without any obvious side effects. This issue was dicovered on RK3566 when adding support for powering off the RK817 PMIC. Signed-off-by: Ondrej Jirman <megous@xxxxxxxxxx> --- drivers/i2c/busses/i2c-rk3x.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/drivers/i2c/busses/i2c-rk3x.c b/drivers/i2c/busses/i2c-rk3x.c index 819ab4ee517e..02ddb237f69a 100644 --- a/drivers/i2c/busses/i2c-rk3x.c +++ b/drivers/i2c/busses/i2c-rk3x.c @@ -423,8 +423,8 @@ static void rk3x_i2c_handle_read(struct rk3x_i2c *i2c, unsigned int ipd) if (!(ipd & REG_INT_MBRF)) return; - /* ack interrupt */ - i2c_writel(i2c, REG_INT_MBRF, REG_IPD); + /* ack interrupt (read also produces a spurious START flag, clear it too) */ + i2c_writel(i2c, REG_INT_MBRF | REG_INT_START, REG_IPD); /* Can only handle a maximum of 32 bytes at a time */ if (len > 32) -- 2.33.0