pm_runtime_get_sync() increments the runtime PM usage counter even the call returns an error code. Thus a pairing decrement is needed on the error handling path to keep the counter balanced. Signed-off-by: Dinghao Liu <dinghao.liu@xxxxxxxxxx> --- drivers/i2c/busses/i2c-stm32f7.c | 4 +++- 1 file changed, 3 insertions(+), 1 deletion(-) diff --git a/drivers/i2c/busses/i2c-stm32f7.c b/drivers/i2c/busses/i2c-stm32f7.c index 330ffed011e0..602cf35649c8 100644 --- a/drivers/i2c/busses/i2c-stm32f7.c +++ b/drivers/i2c/busses/i2c-stm32f7.c @@ -1767,8 +1767,10 @@ static int stm32f7_i2c_reg_slave(struct i2c_client *slave) return ret; ret = pm_runtime_get_sync(dev); - if (ret < 0) + if (ret < 0) { + pm_runtime_put_autosuspend(dev); return ret; + } if (!stm32f7_i2c_is_slave_registered(i2c_dev)) stm32f7_i2c_enable_wakeup(i2c_dev, true); -- 2.17.1