Hi all, We met a issue when use Synopsys DesignWare I2C. The SDA will keep low level and never go back to the high level if both i2c controllers simultaneously access the same i2c device(rtc), then both two i2c controllers can't send any data. we try to reset the rtc, but not working. After reset the i2c controller, the SDA goes back to the high state and we can get time from rtc again. The scenario is as follows, any advice will be appreciated. OS 1 | OS 2 | +--------------+----------|--------------+ | | | | | +---------|----+-----|---------+ | | | | | | | | ---------------- ------ | ----------------- |i2c controller1| | rtc| | |i2c controller2| ---------------- ------ | ----------------- | note: 1) i2c controller1 and controller2 use same IP. 2) OS1 use v3.19 and OS2 use 2.6 Thanks Kefeng -- To unsubscribe from this list: send the line "unsubscribe linux-i2c" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html