On 10/04/2013 03:38 PM, Lars-Peter Clausen wrote: > On 10/04/2013 03:09 PM, Michal Simek wrote: >> >> >> On 10/04/2013 02:12 PM, Lars-Peter Clausen wrote: >>> On 10/04/2013 01:55 PM, Wolfram Sang wrote: >>>> On Fri, Oct 04, 2013 at 11:53:49AM +0200, Michal Simek wrote: >>>>> On 10/04/2013 07:46 AM, Wolfram Sang wrote: >>>>>> >>>>>>> + cr = xiic_getreg32(i2c, XIIC_CR_REG_OFFSET); >>>>>>> + cr |= XIIC_CR_DIR_IS_TX_MASK; >>>>>>> + xiic_setreg32(i2c, XIIC_CR_REG_OFFSET, cr); >>>>>>> + >>>>>> >>>>>> Is there no need to clear the bit again when receiving? >>>>> >>>>> This bit is cleared in xiic_xfer() -> xiic_start_xfer() ->xiic_reinit() >>>>> >>>>> xiic_setreg8(i2c, XIIC_CR_REG_OFFSET, XIIC_CR_TX_FIFO_RESET_MASK); >>>> >>>> A bit implicit, but OK. >>>> >>>>>> And did >>>>>> transferring ever work if this bit was never set before? >>>>> >>>>> I really don't know. We have switched from old driver to this new mainline one >>>>> and based on our eeprom testing we have found that this bit hasn't been setup properly. >>>>> >>>>> It is described here. >>>>> http://www.xilinx.com/support/documentation/ip_documentation/axi_iic/v1_02_a/axi_iic_ds756.pdf >>>>> page 28 - step 3. >>>>> >>>>> IIC Master Transmitter with a Repeated Start >>>>> 1. Write the IIC device address to the TX_FIFO. >>>>> 2. Write data to TX_FIFO. >>>>> 3. Write to Control Register (CR) to set MSMS = 1 and TX = 1. >>>>> 4. Continue writing data to TX_FIFO. >>>>> 5. Wait for transmit FIFO empty interrupt. This implies the IIC has throttled the bus. >>>>> 6. Write to CR to set RSTA = 1. >>>> >>>> Repeated start is not happening in the driver as well, or am I >>>> overlooking something? >>>> >>>>> 7. Write IIC device address to TX_FIFO. >>>>> 8. Write all data except last byte to TX_FIFO. >>>>> 9. Wait for transmit FIFO empty interrupt. This implies the IIC has throttled the bus. >>>>> 10. Write to CR to set MSMS = 0. The IIC generates a stop condition at the end of the last byte. >>>>> 11. Write last byte of data to TX_FIFO. >>>> >>>> CCing more people who worked on the driver in the past and might have >>>> experiences >>> >>> The current version works fine here. The driver uses whats described in the >>> datasheet as "dynamic controller logic flow" and not the "standard >>> controller logic flow". The sequence Michal mentioned above is from the >>> "standard controller logic flow" section. >> >> Does this change break "dynamic controller logic flow"? > > Not sure, but I would assume that the bit is ignored in this mode. But I > don't think the patch should be applied since this step is not in the > sequence of steps that should be done. Kedar: Can you please look at both these modes and provide feedback? Thanks, Michal -- Michal Simek, Ing. (M.Eng), OpenPGP -> KeyID: FE3D1F91 w: www.monstr.eu p: +42-0-721842854 Maintainer of Linux kernel - Microblaze cpu - http://www.monstr.eu/fdt/ Maintainer of Linux kernel - Xilinx Zynq ARM architecture Microblaze U-BOOT custodian and responsible for u-boot arm zynq platform
Attachment:
signature.asc
Description: OpenPGP digital signature