On Thu, Aug 22, 2013 at 04:19:06PM +0200, Gregory CLEMENT wrote: > All the Armada XP (mv78230, mv78260 and mv78460) have a silicon issue > in the I2C controller which violate the i2c repeated start > timing. The I2C standard requires a minimum of 4.7us for the repeated > start condition whereas the I2C controller of the Armada XP this time > is 2.9us. > > So this patch adds a 5us delay for the start case only if the > the compatible i2c-mv78230 is set. > > Based on the initals patches from Zbigniew Bodek > > Signed-off-by: Gregory CLEMENT <gregory.clement@xxxxxxxxxxxxxxxxxx> > Signed-off-by: Zbigniew Bodek <zbb@xxxxxxxxxxxx> Applied to for-next, thanks!