On Thu, 26 Aug 2010, Guenter Roeck wrote: > > > +temp[1-*]_emergency > > > + Temperature emergency value, typically greater than > > > + corresponding temp_crit values. > > > + Unit: millidegree Celsius > > > + RW > > > + > > > > If we have two-level alarms: critical, then emergency, it is best to have > > that written down than to imply it by "typically greater than corresponding > > temp_crit"... > > > How about: > Temperature emergency max value, for chips supporting more than > two upper temperature limits. Must be equal or greater than > corresponding temp_crit values. > Unit: millidegree Celsius > RW Much better, thank you. -- "One disk to rule them all, One disk to find them. One disk to bring them all and in the darkness grind them. In the Land of Redmond where the shadows lie." -- The Silicon Valley Tarot Henrique Holschuh -- To unsubscribe from this list: send the line "unsubscribe linux-i2c" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html