Re: [PATCH] hwmon: (max6697) Document discrepancy in overtemperature status bit values

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Sat, Jul 27, 2024 at 01:20:07PM -0700, Guenter Roeck wrote:
> In the MAX6581 datasheet Revision 0 to 3, the local channel overtemperature
> status is reported in bit 6 of register 0x45, and the overtemperature
> status for remote channel 7 is reported in bit 7. In Revision 4 and later,
> the local channel overtemperature status is reported in bit 7, and the
> remote channel 7 overtemperature status is reported in bit 6. A real
> chip was found to match the functionality documented in Revision 4 and
> later.
> 
> The code was fixed with commit 1ea3fd1eb986 ("hwmon: (max6697) Fix swapped
> temp{1,8} critical alarms"). At that time it looked like this was an
> original bug. It only turned out later that the problem was the result of
> incorrect information in the chip datasheet.
> 
> Document the discrepancy to avoid confusion caused by old versions of the
> datasheet.
> 
> Cc: Tzung-Bi Shih <tzungbi@xxxxxxxxxx>
> Signed-off-by: Guenter Roeck <linux@xxxxxxxxxxxx>

Reviewed-by: Tzung-Bi Shih <tzungbi@xxxxxxxxxx>