Add a property to the binding to configure the Alert Polarity. Alert pin is asserted based on the value of Alert Polarity bit of Mask/Enable register. It is by default 0 which means Alert pin is configured to be active low. To configure it to active high, set alert-polarity property value to 1. Signed-off-by: Amna Waseem <Amna.Waseem@xxxxxxxx> --- Documentation/devicetree/bindings/hwmon/ti,ina2xx.yaml | 9 +++++++++ 1 file changed, 9 insertions(+) diff --git a/Documentation/devicetree/bindings/hwmon/ti,ina2xx.yaml b/Documentation/devicetree/bindings/hwmon/ti,ina2xx.yaml index df86c2c92037..a3f0fd71fcc6 100644 --- a/Documentation/devicetree/bindings/hwmon/ti,ina2xx.yaml +++ b/Documentation/devicetree/bindings/hwmon/ti,ina2xx.yaml @@ -66,6 +66,14 @@ properties: description: phandle to the regulator that provides the VS supply typically in range from 2.7 V to 5.5 V. + alert-polarity: + description: | + Alert polarity bit value of Mask/Enable register. Alert pin is asserted + based on the value of Alert polarity Bit. Default value is active low. + 0 selects active low, 1 selects active high. + $ref: /schemas/types.yaml#/definitions/uint32 + enum: [0, 1] + required: - compatible - reg @@ -88,5 +96,6 @@ examples: label = "vdd_3v0"; shunt-resistor = <1000>; vs-supply = <&vdd_3v0>; + alert-polarity = <1>; }; }; -- 2.30.2