[PATCH 4/4] ABI: sysfs-class-hwmon: document emergency/max/min temperature alarms

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



These attributes are widely used in the hwmon subsystem, but they still
must be documented.

Add tempY_emergency_alarm, tempY_max_alarm and tempY_min_alarm to the
ABI documentation according to their current usage and access rights in
the hwmon subsystem.

Signed-off-by: Javier Carrasco <javier.carrasco.cruz@xxxxxxxxx>
---
 Documentation/ABI/testing/sysfs-class-hwmon | 27 +++++++++++++++++++++++++++
 1 file changed, 27 insertions(+)

diff --git a/Documentation/ABI/testing/sysfs-class-hwmon b/Documentation/ABI/testing/sysfs-class-hwmon
index 3d5e6142ef0c..3dac923c9b0e 100644
--- a/Documentation/ABI/testing/sysfs-class-hwmon
+++ b/Documentation/ABI/testing/sysfs-class-hwmon
@@ -381,6 +381,15 @@ Description:
 
 		RW
 
+What:		/sys/class/hwmon/hwmonX/tempY_max_alarm
+Description:
+		Maximum temperature alarm flag.
+
+		- 0: OK
+		- 1: temperature has reached tempY_max
+
+		RO
+
 What:		/sys/class/hwmon/hwmonX/tempY_min
 Description:
 		Temperature min value.
@@ -389,6 +398,15 @@ Description:
 
 		RW
 
+What:		/sys/class/hwmon/hwmonX/tempY_min_alarm
+Description:
+		Minimum temperature alarm flag.
+
+		- 0: OK
+		- 1: temperature has reached tempY_min
+
+		RO
+
 What:		/sys/class/hwmon/hwmonX/tempY_max_hyst
 Description:
 		Temperature hysteresis value for max limit.
@@ -457,6 +475,15 @@ Description:
 
 		RW
 
+What:		/sys/class/hwmon/hwmonX/tempY_emergency_alarm
+Description:
+		Emergency high temperature alarm flag.
+
+		- 0: OK
+		- 1: temperature has reached tempY_emergency
+
+		RO
+
 What:		/sys/class/hwmon/hwmonX/tempY_emergency_hyst
 Description:
 		Temperature hysteresis value for emergency limit.

-- 