[PATCH v3 2/5] dt-bindings: hwmon: Add possible new properties to max31827 bindings

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



These modify the corresponding bits in the configuration register.

adi,comp-int is a hardware property, because it affects the behavior
of the interrupt signal and whatever it is connected to.

adi,timeout-enable is a hardware property, because it affects i2c
bus operation.

Signed-off-by: Daniel Matyas <daniel.matyas@xxxxxxxxxx>
---

v2 -> v3: Changed commit subject and message

v1 -> v2: Added adi,timeout-enable property to binding. Fixed
dt_binding_check errors.

 .../bindings/hwmon/adi,max31827.yaml          | 35 +++++++++++++++++++
 1 file changed, 35 insertions(+)

diff --git a/Documentation/devicetree/bindings/hwmon/adi,max31827.yaml b/Documentation/devicetree/bindings/hwmon/adi,max31827.yaml
index 2dc8b07b4d3b..6bde71bdb8dd 100644
--- a/Documentation/devicetree/bindings/hwmon/adi,max31827.yaml
+++ b/Documentation/devicetree/bindings/hwmon/adi,max31827.yaml
@@ -32,6 +32,37 @@ properties:
       Must have values in the interval (1.6V; 3.6V) in order for the device to
       function correctly.
 
+  adi,comp-int:
+    description:
+      If present interrupt mode is used. If not present comparator mode is used
+      (default).
+    type: boolean
+
+  adi,alrm-pol:
+    description:
+      Sets the alarms active state.
+            - 0 = active low
+            - 1 = active high
+      For max31827 and max31828 the default alarm polarity is low. For max31829
+      it is high.
+    $ref: /schemas/types.yaml#/definitions/uint32
+    enum: [0, 1]
+
+  adi,flt-q:
+    description:
+      Select how many consecutive temperature faults must occur before
+      overtemperature or undertemperature faults are indicated in the
+      corresponding status bits.
+      For max31827 default fault queue is 1. For max31828 and max31829 it is 4.
+    $ref: /schemas/types.yaml#/definitions/uint32
+    enum: [1, 2, 4, 8]
+
+  adi,timeout-enable:
+    description:
+      Enables timeout. Bus timeout resets the I2C-compatible interface when SCL
+      is low for more than 30ms (nominal).
+    type: boolean
+
 required:
   - compatible
   - reg
@@ -49,6 +80,10 @@ examples:
             compatible = "adi,max31827";
             reg = <0x42>;
             vref-supply = <&reg_vdd>;
+            adi,comp-int;
+            adi,alrm-pol = <0>;
+            adi,flt-q = <1>;
+            adi,timeout-enable;
         };
     };
 ...
-- 
2.34.1