From: Tao Ren <rentao.bupt@xxxxxxxxx> Skip status check for both pfe1100 and pfe3000 because the communication error is also observed on pfe1100 devices. Signed-off-by: Tao Ren <rentao.bupt@xxxxxxxxx> --- Changes in v2: - improving comments. - removing unnecessary {} drivers/hwmon/pmbus/bel-pfe.c | 16 ++++++++-------- 1 file changed, 8 insertions(+), 8 deletions(-) diff --git a/drivers/hwmon/pmbus/bel-pfe.c b/drivers/hwmon/pmbus/bel-pfe.c index fa5070ae26bc..7c5f4b10a7c1 100644 --- a/drivers/hwmon/pmbus/bel-pfe.c +++ b/drivers/hwmon/pmbus/bel-pfe.c @@ -17,12 +17,13 @@ enum chips {pfe1100, pfe3000}; /* - * Disable status check for pfe3000 devices, because some devices report - * communication error (invalid command) for VOUT_MODE command (0x20) - * although correct VOUT_MODE (0x16) is returned: it leads to incorrect - * exponent in linear mode. + * Disable status check because some devices report communication error + * (invalid command) for VOUT_MODE command (0x20) although the correct + * VOUT_MODE (0x16) is returned: it leads to incorrect exponent in linear + * mode. + * This affects both pfe3000 and pfe1100. */ -static struct pmbus_platform_data pfe3000_plat_data = { +static struct pmbus_platform_data pfe_plat_data = { .flags = PMBUS_SKIP_STATUS_CHECK, }; @@ -94,16 +95,15 @@ static int pfe_pmbus_probe(struct i2c_client *client) int model; model = (int)i2c_match_id(pfe_device_id, client)->driver_data; + client->dev.platform_data = &pfe_plat_data; /* * PFE3000-12-069RA devices may not stay in page 0 during device * probe which leads to probe failure (read status word failed). * So let's set the device to page 0 at the beginning. */ - if (model == pfe3000) { - client->dev.platform_data = &pfe3000_plat_data; + if (model == pfe3000) i2c_smbus_write_byte_data(client, PMBUS_PAGE, 0); - } return pmbus_do_probe(client, &pfe_driver_info[model]); } -- 2.40.1