On Thu, Apr 13, 2023 at 04:39:58PM -0500, Babu Moger wrote: > From: Babu Moger <Babu.Moger@xxxxxxx> > > Spec says, when CUR_TEMP_TJ_SEL == 3 and CUR_TEMP_RANGE_SEL == 0, > it should use RangeUnadjusted is 0, which is (CurTmp*0.125 -49) C. The > CUR_TEMP register is read-write when CUR_TEMP_TJ_SEL == 3 (bit 17-16). > > Add the check to detect it. > > Sensors command's output before the patch. > $sensors > k10temp-pci-00c3 > Adapter: PCI adapter > Tctl: +76.6°C <- Wrong value > Tccd1: +26.5°C > Tccd2: +27.5°C > Tccd3: +27.2°C > Tccd4: +27.5°C > Tccd5: +26.0°C > Tccd6: +26.2°C > Tccd7: +25.0°C > Tccd8: +26.5°C > > Sensors command's output after the patch. > $sensors > k10temp-pci-00c3 > Adapter: PCI adapter > Tctl: +28.8°C <- corrected value > Tccd1: +27.5°C > Tccd2: +28.5°C > Tccd3: +28.5°C > Tccd4: +28.5°C > Tccd5: +27.0°C > Tccd6: +27.5°C > Tccd7: +27.0°C > Tccd8: +27.5°C > > Signed-off-by: Babu Moger <babu.moger@xxxxxxx> Applied. Please update your e-mail address configuration to avoid the following checkpatch message. CHECK: From:/Signed-off-by: email comments mismatch: 'From: Babu Moger <Babu.Moger@xxxxxxx>' != 'Signed-off-by: Babu Moger <babu.moger@xxxxxxx>' Thanks, Guenter