On 4/10/23 17:40, Guenter Roeck wrote:
On 4/10/23 01:19, Matti Vaittinen wrote:
to 6. huhtik. 2023 klo 16.43 Mark Brown (broonie@xxxxxxxxxx) kirjoitti:

On Thu, Apr 06, 2023 at 11:00:02AM +0300, Matti Vaittinen wrote:
ke 5. huhtik. 2023 klo 18.19 Mark Brown (broonie@xxxxxxxxxx) kirjoitti:
On Wed, Apr 05, 2023 at 07:18:32AM -0700, Guenter Roeck wrote:

It can also try to avoid
interacting with hardware if that might not work.

It'd be great to have documentation / specification for sending and/or
handling the regulator events. I don't think we currently have such.
As far as I understand, the notifications can be picked up by all
consumers of a regulator. I am a bit worried about:
a) Situations where notification handlers 'collide' by doing 'actions'
which are unexpected by other handlers

I'm not sure what you're expecting there?  A device working with itself
shouldn't disrupt any other users.

I have no concrete idea, just a vague uneasy feeling knowing that
devices tend to interact with each other. I guess it is more about the
amount of uncertainty caused by my lack of knowledge regarding what
could be done by these handlers. So, as I already said - if no one
else is bothered by this then I definitely don't want to block the
series. Still, if the error handling should be kept internal to PMBus
- then we should probably either say that consumer drivers must not
(forcibly) turn off the supply when receiving these notifications - or
not send these notifications from PMBus and allow PMBus to decide
error handling internally. (Again, I don't know if any in-tree
consumer drivers do turn off the supply regulator in error handlers -
but I don't think it is actually forbidden). Or am I just making  a
problem that does not exist?


For my part I (still) don't understand why this is considered a problem
for this driver but not for all the other drivers reporting various
error conditions to the regulator subsystem. At least some of them
also have programmable reaction to such error conditions.

I may not know the drivers you're referring to. And, as I said, maybe there is no problem.

To explain why I asked this question for this driver:

What caught my attention was use of the REGULATOR_EVENT_*_WARN flags, which were originally added so regulators could be flagging 'not yet critical'-errors Vs. the other, older REGULATOR_EVENT_* flags. From the discussions I have understood the older flags were informing severe hardware failures where system is typically thought to be no longer usable. I have understood that the most likely handling for such notification is shutting off the regulator. I have further understood that there are not many consumers doing handling of these events. (This is all just my understanding based on discussions - take it with grain of salt).

I was the one who added these warning level notifications. Thus, I have been following (only) use of those warnings. I have no proper insight to existing drivers using all these flags.

When grepping for the WARNING level regulator events I can find following drivers:
drivers/regulator/bd9576-regulator.c
drivers/regulator/max597x-regulator.c
drivers/regulator/tps65219-regulator.c

The difference (in my head) between these and PMBus-core is that these are very specific PMIC ICs. The board designer should have a good understanding which of the power-rails may have 'warning level' failures, and which errors are 'critical'. They should select and set the IRQ limits and error severities in the device-tree accordingly.

PMBus core (again, in my head) is more generic purpose system. This is why I originally asked if the 'error severity' in PMBus specifies also the error handling - and if these regulator notifications map to intended handling. Now, after this discussion I think that:

PMBus has it's own error-handling which is implemented independently from these notifications. This handling should not be messed-up by regulator consumers, for example by touching the regulator state.

This is what made me think sending regulator notifications might not be the best approach - (but as I said, I may be wrong. I am no longer sure what kind of handling there is expected for these events. Furthermore, as we see below, I did not find in-tree consumers taking "radical" actions when receiving the notifications).

Yep, I didn't find other in-tree consumers for these notifications except:
drivers/usb/host/ohci-da8xx.c

(I was not thorough so may have missed some, but seems there is not many in-tree consumers.)

I did only a very very brief shallow peek but it seems to me that even there driver only sets a flag - which is used in debug message. (I may have missed something here as well).

Judging this it seems to me that, at the moment, these notifications are mostly ignored by consumers - and they are sent by only a handful of devices. There probably exist some downstream users for those, but I have not heard of them. Maybe they are only used on very specific systems. This could explain why there has been no problems.

I know, I know. Lot's of guessing, assuming and hand waving. Sorry :/

Yours,
	-- Matti.

--