On Wed, Sep 21, 2022 at 1:18 PM Eliav Farber <farbere@xxxxxxxxxx> wrote: > > Modify the equation and coefficients used to convert the digital output > to temperature according to series 5 of the Moortec Embedded Temperature > Sensor (METS) datasheet: > T = G + H * (n / cal5 - 0.5) + J * F > > Where: > *) G = 60, H = 200, cal5 = 4094, J = -0.1. > *) F = frequency clock in MHz. > *) n is the digital output. > > In code, the G, H and J coefficients are multiplied by a factor of 1000 > to get the temperature in milli-Celsius. > Final result is clamped in case it exceeds min/max thresholds. > > Change is done since it is unclear where the current equation and > coefficients came from. > > Signed-off-by: Eliav Farber <farbere@xxxxxxxxxx> > Reviewed-by: Andy Shevchenko <andriy.shevchenko@xxxxxxxxxxxxxxx> > Reported-by: kernel test robot <lkp@xxxxxxxxx> Only build tested on top of next-20220921 after reverting v5 patches. Tested-by: Sudip Mukherjee <sudipm.mukherjee@xxxxxxxxx> -- Regards Sudip