On Thu, Sep 08, 2022 at 03:24:47PM +0000, Eliav Farber wrote: > Use thermal coefficients from the device tree if they exist. > Otherwise, use default values according to the series (5 or 6). > All coefficients can be used or only part of them. > > The coefficients shall be used for fine tuning the default values since > coefficients can vary between product and product. > > Signed-off-by: Eliav Farber <farbere@xxxxxxxxxx> > Reviewed-by: Andy Shevchenko <andriy.shevchenko@xxxxxxxxxxxxxxx> Applied to hwmon-next. Thanks, Guenter