If there is an input undervoltage fault, reported in STATUS_INPUT command response, there is quite likely a "Unit Off For Insufficient Input Voltage" condition as well. Add a constant for bit 3 of STATUS_INPUT. Update the Vin limit attributes to include both bits in the mask for clearing faults. If an input undervoltage fault occurs, causing a unit off for insufficient input voltage, but the unit is off bit is not cleared, the STATUS_WORD will not be updated to clear the input fault condition. Including the unit is off bit (bit 3) allows for the input fault condition to completely clear. Signed-off-by: Brandon Wyman <bjwyman@xxxxxxxxx> --- drivers/hwmon/pmbus/pmbus.h | 1 + drivers/hwmon/pmbus/pmbus_core.c | 2 +- 2 files changed, 2 insertions(+), 1 deletion(-) diff --git a/drivers/hwmon/pmbus/pmbus.h b/drivers/hwmon/pmbus/pmbus.h index e0aa8aa46d8c..ef3a8ecde4df 100644 --- a/drivers/hwmon/pmbus/pmbus.h +++ b/drivers/hwmon/pmbus/pmbus.h @@ -319,6 +319,7 @@ enum pmbus_fan_mode { percent = 0, rpm }; /* * STATUS_VOUT, STATUS_INPUT */ +#define PB_VOLTAGE_VIN_OFF BIT(3) #define PB_VOLTAGE_UV_FAULT BIT(4) #define PB_VOLTAGE_UV_WARNING BIT(5) #define PB_VOLTAGE_OV_WARNING BIT(6) diff --git a/drivers/hwmon/pmbus/pmbus_core.c b/drivers/hwmon/pmbus/pmbus_core.c index ac2fbee1ba9c..a0d899dc81f0 100644 --- a/drivers/hwmon/pmbus/pmbus_core.c +++ b/drivers/hwmon/pmbus/pmbus_core.c @@ -1373,7 +1373,7 @@ static const struct pmbus_limit_attr vin_limit_attrs[] = { .reg = PMBUS_VIN_UV_FAULT_LIMIT, .attr = "lcrit", .alarm = "lcrit_alarm", - .sbit = PB_VOLTAGE_UV_FAULT, + .sbit = (PB_VOLTAGE_UV_FAULT | PB_VOLTAGE_VIN_OFF), }, { .reg = PMBUS_VIN_OV_WARN_LIMIT, .attr = "max", -- 2.25.1