[PATCH AUTOSEL 4.9 1/4] hwmon: (lm90) Do not report 'busy' status bit as alarm

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



From: Guenter Roeck <linux@xxxxxxxxxxxx>

[ Upstream commit cdc5287acad9ede121924a9c9313544b80d15842 ]

Bit 7 of the status register indicates that the chip is busy
doing a conversion. It does not indicate an alarm status.
Stop reporting it as alarm status bit.

Signed-off-by: Guenter Roeck <linux@xxxxxxxxxxxx>
Signed-off-by: Sasha Levin <sashal@xxxxxxxxxx>
---
 drivers/hwmon/lm90.c | 3 ++-
 1 file changed, 2 insertions(+), 1 deletion(-)

diff --git a/drivers/hwmon/lm90.c b/drivers/hwmon/lm90.c
index 293d1184976b3..ba659182d77a0 100644
--- a/drivers/hwmon/lm90.c
+++ b/drivers/hwmon/lm90.c
@@ -196,6 +196,7 @@ enum chips { lm90, adm1032, lm99, lm86, max6657, max6659, adt7461, max6680,
 #define LM90_STATUS_RHIGH	(1 << 4) /* remote high temp limit tripped */
 #define LM90_STATUS_LLOW	(1 << 5) /* local low temp limit tripped */
 #define LM90_STATUS_LHIGH	(1 << 6) /* local high temp limit tripped */
+#define LM90_STATUS_BUSY	(1 << 7) /* conversion is ongoing */
 
 #define MAX6696_STATUS2_R2THRM	(1 << 1) /* remote2 THERM limit tripped */
 #define MAX6696_STATUS2_R2OPEN	(1 << 2) /* remote2 is an open circuit */
@@ -692,7 +693,7 @@ static int lm90_update_device(struct device *dev)
 		val = lm90_read_reg(client, LM90_REG_R_STATUS);
 		if (val < 0)
 			return val;
-		data->alarms = val;	/* lower 8 bit of alarms */
+		data->alarms = val & ~LM90_STATUS_BUSY;
 
 		if (data->kind == max6696) {
 			val = lm90_select_remote_channel(client, data, 1);
-- 
2.34.1