On Tue, Apr 20, 2021 at 12:15:40PM CDT, Mark Brown wrote:
On Tue, Apr 20, 2021 at 11:40:24AM -0500, Zev Weiss wrote:
On Tue, Apr 20, 2021 at 11:13:18AM CDT, Mark Brown wrote:

> I already suggested writing a driver or drivers that represent the
> hardware you have, that advice remains.  It's hard to follow what you
> were trying to say with your long mail earlier today but it seems like

That email was an attempt to explain why writing a driver for the specific
hardware devices we're powering seems like a poor fit to me.  To summarize:

 - There's a wide variety of different devices potentially behind an
LM25066.

This is true for lots of hardware, we still integrate things into
frameworks.

 - A hypothetical driver for any one of them would be completely
non-specific to that device and functionally identical to a driver    for
any other, because the only hardware it would actually be    touching is the
LM25066, and in ways that are again completely    non-specific to anything
but the LM25066 itself.

I don't see why that would be the case at all.  Even within the indended
application as a power controller for a hotpluggable bus there's plenty
of potential for integration into a wider representation of the socket
things get inserted into - for example I've worked with buses that had
support for operator signalling of hotplug (buttons to press to initiate
hot removal, with lights to signal when a clean shutdown of the card had
been completed), you might also want to have additional environment
monitoring and of course the labelling that I mentioned in an earlier
post.  I can imagine you probably have some other connection of some
kind to the host too (eg, network ports) to join up and perhaps sync
hotplug for.


Consider the power shelf I mentioned earlier -- it's a rackmount power supply and that's about it. It provides DC power to arbitrary devices that it has no other connection to, just ground and +12V. Those devices might be servers, or cooling fans, or vacuum cleaners or floodlights -- the power shelf doesn't know, or care. It's a lot like a switchable network PDU in that it just provides a way for an operator to remotely cut power to a thing that's plugged into it. There's no other bus or anything in the picture. (And pragmatically, given that its most common usage is likely to be to provide a cold power cycle as a last-ditch recovery option when things are wedged in some unresponsive state, attempting any sort of coordination with the downstream device would probably be a dead end anyway.)