Change initial PWM target to 255 to prevent overheating, for example when BMC hangs in userspace or when userspace fan control application is not implemented yet. Signed-off-by: Kun Yi <kunyi@xxxxxxxxxx> --- drivers/hwmon/npcm750-pwm-fan.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/hwmon/npcm750-pwm-fan.c b/drivers/hwmon/npcm750-pwm-fan.c index 96634fd54e0b..c0fab54c0094 100644 --- a/drivers/hwmon/npcm750-pwm-fan.c +++ b/drivers/hwmon/npcm750-pwm-fan.c @@ -52,7 +52,7 @@ /* Define the Counter Register, value = 100 for match 100% */ #define NPCM7XX_PWM_COUNTER_DEFAULT_NUM 255 -#define NPCM7XX_PWM_CMR_DEFAULT_NUM 127 +#define NPCM7XX_PWM_CMR_DEFAULT_NUM 255 #define NPCM7XX_PWM_CMR_MAX 255 /* default all PWM channels PRESCALE2 = 1 */ -- 2.19.0.605.g01d371f741-goog