Re: [PATCH v2 0/2] scpi-sensors: Fix SCP sensor readings scale

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Wed, Mar 08, 2017 at 09:24:38AM +0100, Carlo Caione wrote:
> On Fri, Mar 3, 2017 at 10:14 AM, Carlo Caione <carlo@xxxxxxxxxx> wrote:
> > From: Carlo Caione <carlo@xxxxxxxxxxxx>
> >
> > The implementation details for SCPI seems to suggest that the sensor
> > readings must be reported by SCP using a well defined scale
> > (millidegree Celsius for temperature, millivolts for voltage,
> > milliamperes for current, microwatts for power and microjoules for
> > energy).
> >
> > This is also important for the interaction with other subsystems: for
> > example both the thermal sub-system and the hwmon sysfs interface expect
> > the temperature expressed in millidegree Celsius.
> >
> > Unfortunately since this behaviour is dependent on the firmware
> > implementation there are cases where the sensor readings are reported
> > using a different scale. For example in the Amlogic SoCs the
> > temperature is reported in degree and not millidegree Celsius.
> >
> > In this patchset we introduce a new DT property `scpi,sensors-scale` that is
> > used by the scpi-hwmon driver to convert the sensor readings to the expected
> > scale.
> >
> > v2:
> >  - Added data validation (scale != 0)
> >  - s/unsigned int/u32/ for the array
> >  - Switched to array initialiser notation
> >  - Introduced scpi_scale_reading()
> 
> gentle ping
> 

Waiting for Rob to provide feedback on the devicetree property.

Guenter
--
To unsubscribe from this list: send the line "unsubscribe linux-hwmon" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html



[Index of Archives]     [LM Sensors]     [Linux Sound]     [ALSA Users]     [ALSA Devel]     [Linux Audio Users]     [Linux Media]     [Kernel]     [Gimp]     [Yosemite News]     [Linux Media]

  Powered by Linux