Due to lack of maintainance and stall of development for a few years now, and since no new features will ever be added upstream, remove the OX810 and OX820 timer bindings. Signed-off-by: Neil Armstrong <neil.armstrong@xxxxxxxxxx> --- .../devicetree/bindings/timer/oxsemi,rps-timer.txt | 17 ----------------- 1 file changed, 17 deletions(-) diff --git a/Documentation/devicetree/bindings/timer/oxsemi,rps-timer.txt b/Documentation/devicetree/bindings/timer/oxsemi,rps-timer.txt deleted file mode 100644 index d191612539e8..000000000000 --- a/Documentation/devicetree/bindings/timer/oxsemi,rps-timer.txt +++ /dev/null @@ -1,17 +0,0 @@ -Oxford Semiconductor OXNAS SoCs Family RPS Timer -================================================ - -Required properties: -- compatible: Should be "oxsemi,ox810se-rps-timer" or "oxsemi,ox820-rps-timer" -- reg : Specifies base physical address and size of the registers. -- interrupts : The interrupts of the two timers -- clocks : The phandle of the timer clock source - -example: - -timer0: timer@200 { - compatible = "oxsemi,ox810se-rps-timer"; - reg = <0x200 0x40>; - clocks = <&rpsclk>; - interrupts = <4 5>; -}; -- 2.34.1