[PATCH v6 1/3] nvme: enable FDP support

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Flexible Data Placement (FDP), as ratified in TP 4146a, allows the host
to control the placement of logical blocks so as to reduce the SSD WAF.

Userspace can send the data lifetime information using the write hints.
The SCSI driver (sd) can already pass this information to the SCSI
devices. This patch does the same for NVMe.

Fetch the placement-identifiers if the device supports FDP.
The incoming write-hint is mapped to a placement-identifier, which in
turn is set in the DSPEC field of the write command.

Signed-off-by: Kanchan Joshi <joshi.k@xxxxxxxxxxx>
Signed-off-by: Hui Qi <hui81.qi@xxxxxxxxxxx>
Signed-off-by: Nitesh Shetty <nj.shetty@xxxxxxxxxxx>
---
 drivers/nvme/host/core.c | 70 ++++++++++++++++++++++++++++++++++++++++
 drivers/nvme/host/nvme.h |  4 +++
 include/linux/nvme.h     | 19 +++++++++++
 3 files changed, 93 insertions(+)

diff --git a/drivers/nvme/host/core.c b/drivers/nvme/host/core.c
index ca9959a8fb9e..7fb3ed4fe9c0 100644
--- a/drivers/nvme/host/core.c
+++ b/drivers/nvme/host/core.c
@@ -44,6 +44,20 @@ struct nvme_ns_info {
 	bool is_removed;
 };
 
+struct nvme_fdp_ruh_status_desc {
+	u16 pid;
+	u16 ruhid;
+	u32 earutr;
+	u64 ruamw;
+	u8  rsvd16[16];
+};
+
+struct nvme_fdp_ruh_status {
+	u8  rsvd0[14];
+	__le16 nruhsd;
+	struct nvme_fdp_ruh_status_desc ruhsd[];
+};
+
 unsigned int admin_timeout = 60;
 module_param(admin_timeout, uint, 0644);
 MODULE_PARM_DESC(admin_timeout, "timeout in seconds for admin commands");
@@ -959,6 +973,19 @@ static bool nvme_valid_atomic_write(struct request *req)
 	return true;
 }
 
+static inline void nvme_assign_placement_id(struct nvme_ns *ns,
+					struct request *req,
+					struct nvme_command *cmd)
+{
+	enum rw_hint h = req->write_hint;
+
+	if (h >= ns->head->nr_plids)
+		return;
+
+	cmd->rw.control |= cpu_to_le16(NVME_RW_DTYPE_DPLCMT);
+	cmd->rw.dsmgmt |= cpu_to_le32(ns->head->plids[h] << 16);
+}
+
 static inline blk_status_t nvme_setup_rw(struct nvme_ns *ns,
 		struct request *req, struct nvme_command *cmnd,
 		enum nvme_opcode op)
@@ -1078,6 +1105,8 @@ blk_status_t nvme_setup_cmd(struct nvme_ns *ns, struct request *req)
 		break;
 	case REQ_OP_WRITE:
 		ret = nvme_setup_rw(ns, req, cmd, nvme_cmd_write);
+		if (!ret && ns->head->nr_plids)
+			nvme_assign_placement_id(ns, req, cmd);
 		break;
 	case REQ_OP_ZONE_APPEND:
 		ret = nvme_setup_rw(ns, req, cmd, nvme_cmd_zone_append);
@@ -2114,6 +2143,40 @@ static int nvme_update_ns_info_generic(struct nvme_ns *ns,
 	return ret;
 }
 
+static int nvme_fetch_fdp_plids(struct nvme_ns *ns, u32 nsid)
+{
+	struct nvme_command c = {};
+	struct nvme_fdp_ruh_status *ruhs;
+	struct nvme_fdp_ruh_status_desc *ruhsd;
+	int size, ret, i;
+
+	size = struct_size(ruhs, ruhsd, NVME_MAX_PLIDS);
+	ruhs = kzalloc(size, GFP_KERNEL);
+	if (!ruhs)
+		return -ENOMEM;
+
+	c.imr.opcode = nvme_cmd_io_mgmt_recv;
+	c.imr.nsid = cpu_to_le32(nsid);
+	c.imr.mo = 0x1;
+	c.imr.numd =  cpu_to_le32((size >> 2) - 1);
+
+	ret = nvme_submit_sync_cmd(ns->queue, &c, ruhs, size);
+	if (ret)
+		goto out;
+
+	ns->head->nr_plids = le16_to_cpu(ruhs->nruhsd);
+	ns->head->nr_plids =
+		min_t(u16, ns->head->nr_plids, NVME_MAX_PLIDS);
+
+	for (i = 0; i < ns->head->nr_plids; i++) {
+		ruhsd = &ruhs->ruhsd[i];
+		ns->head->plids[i] = le16_to_cpu(ruhsd->pid);
+	}
+out:
+	kfree(ruhs);
+	return ret;
+}
+
 static int nvme_update_ns_info_block(struct nvme_ns *ns,
 		struct nvme_ns_info *info)
 {
@@ -2205,6 +2268,13 @@ static int nvme_update_ns_info_block(struct nvme_ns *ns,
 		if (ret && !nvme_first_scan(ns->disk))
 			goto out;
 	}
+	if (ns->ctrl->ctratt & NVME_CTRL_ATTR_FDPS) {
+		ret = nvme_fetch_fdp_plids(ns, info->nsid);
+		if (ret)
+			dev_warn(ns->ctrl->device,
+				"FDP failure status:0x%x\n", ret);
+	}
+
 
 	ret = 0;
 out:
diff --git a/drivers/nvme/host/nvme.h b/drivers/nvme/host/nvme.h
index 313a4f978a2c..a959a9859e8b 100644
--- a/drivers/nvme/host/nvme.h
+++ b/drivers/nvme/host/nvme.h
@@ -454,6 +454,8 @@ struct nvme_ns_ids {
 	u8	csi;
 };
 
+#define NVME_MAX_PLIDS   (WRITE_LIFE_EXTREME + 1)
+
 /*
  * Anchor structure for namespaces.  There is one for each namespace in a
  * NVMe subsystem that any of our controllers can see, and the namespace
@@ -490,6 +492,8 @@ struct nvme_ns_head {
 	struct device		cdev_device;
 
 	struct gendisk		*disk;
+	u16			nr_plids;
+	u16			plids[NVME_MAX_PLIDS];
 #ifdef CONFIG_NVME_MULTIPATH
 	struct bio_list		requeue_list;
 	spinlock_t		requeue_lock;
diff --git a/include/linux/nvme.h b/include/linux/nvme.h
index b58d9405d65e..a954eaee5b0f 100644
--- a/include/linux/nvme.h
+++ b/include/linux/nvme.h
@@ -275,6 +275,7 @@ enum nvme_ctrl_attr {
 	NVME_CTRL_ATTR_HID_128_BIT	= (1 << 0),
 	NVME_CTRL_ATTR_TBKAS		= (1 << 6),
 	NVME_CTRL_ATTR_ELBAS		= (1 << 15),
+	NVME_CTRL_ATTR_FDPS		= (1 << 19),
 };
 
 struct nvme_id_ctrl {
@@ -843,6 +844,7 @@ enum nvme_opcode {
 	nvme_cmd_resv_register	= 0x0d,
 	nvme_cmd_resv_report	= 0x0e,
 	nvme_cmd_resv_acquire	= 0x11,
+	nvme_cmd_io_mgmt_recv	= 0x12,
 	nvme_cmd_resv_release	= 0x15,
 	nvme_cmd_zone_mgmt_send	= 0x79,
 	nvme_cmd_zone_mgmt_recv	= 0x7a,
@@ -864,6 +866,7 @@ enum nvme_opcode {
 		nvme_opcode_name(nvme_cmd_resv_register),	\
 		nvme_opcode_name(nvme_cmd_resv_report),		\
 		nvme_opcode_name(nvme_cmd_resv_acquire),	\
+		nvme_opcode_name(nvme_cmd_io_mgmt_recv),	\
 		nvme_opcode_name(nvme_cmd_resv_release),	\
 		nvme_opcode_name(nvme_cmd_zone_mgmt_send),	\
 		nvme_opcode_name(nvme_cmd_zone_mgmt_recv),	\
@@ -1015,6 +1018,7 @@ enum {
 	NVME_RW_PRINFO_PRCHK_GUARD	= 1 << 12,
 	NVME_RW_PRINFO_PRACT		= 1 << 13,
 	NVME_RW_DTYPE_STREAMS		= 1 << 4,
+	NVME_RW_DTYPE_DPLCMT		= 2 << 4,
 	NVME_WZ_DEAC			= 1 << 9,
 };
 
@@ -1102,6 +1106,20 @@ struct nvme_zone_mgmt_recv_cmd {
 	__le32			cdw14[2];
 };
 
+struct nvme_io_mgmt_recv_cmd {
+	__u8			opcode;
+	__u8			flags;
+	__u16			command_id;
+	__le32			nsid;
+	__le64			rsvd2[2];
+	union nvme_data_ptr	dptr;
+	__u8			mo;
+	__u8			rsvd11;
+	__u16			mos;
+	__le32			numd;
+	__le32			cdw12[4];
+};
+
 enum {
 	NVME_ZRA_ZONE_REPORT		= 0,
 	NVME_ZRASF_ZONE_REPORT_ALL	= 0,
@@ -1822,6 +1840,7 @@ struct nvme_command {
 		struct nvmf_auth_receive_command auth_receive;
 		struct nvme_dbbuf dbbuf;
 		struct nvme_directive_cmd directive;
+		struct nvme_io_mgmt_recv_cmd imr;
 	};
 };
 
-- 
2.25.1





[Index of Archives]     [Linux Ext4 Filesystem]     [Union Filesystem]     [Filesystem Testing]     [Ceph Users]     [Ecryptfs]     [NTFS 3]     [AutoFS]     [Kernel Newbies]     [Share Photos]     [Security]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux Cachefs]     [Reiser Filesystem]     [Linux RAID]     [NTFS 3]     [Samba]     [Device Mapper]     [CEPH Development]

  Powered by Linux