[PATCH v4 0/2] Prevent re-use of FUSE superblock after force unmount

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Force unmount of fuse severes the connection between FUSE driver and its
userspace counterpart. However, open file handles will prevent the
superblock from being reclaimed. An attempt to remount the filesystem at
the same endpoint will try re-using the superblock, if still present.
Since the superblock re-use path doesn't go through the fs-specific
superblock setup code, its state in FUSE case is already disfunctional,
and that will prevent the mount from succeeding.

Changes in v4:
- Simplify condition according to Christoph Hellwig's comments.

Changes in v3:
- Back to state tracking from v1
- Use s_iflag to mark superblocked ignored
- Only unregister private bdi in retire, without freeing

Changes in v2:
- Remove super from list of superblocks instead of using a flag

Daniil Lunev (2):
  fs/super: function to prevent super re-use
  FUSE: Retire superblock on force unmount

 fs/fuse/inode.c    |  7 +++++--
 fs/super.c         | 28 ++++++++++++++++++++++++++--
 include/linux/fs.h |  2 ++
 3 files changed, 33 insertions(+), 4 deletions(-)

-- 
2.31.0




[Index of Archives]     [Linux Ext4 Filesystem]     [Union Filesystem]     [Filesystem Testing]     [Ceph Users]     [Ecryptfs]     [NTFS 3]     [AutoFS]     [Kernel Newbies]     [Share Photos]     [Security]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux Cachefs]     [Reiser Filesystem]     [Linux RAID]     [NTFS 3]     [Samba]     [Device Mapper]     [CEPH Development]