On 4/27/22 09:02, Pankaj Raghav wrote:
Remove the condition which disallows non-power_of_2 zone size ZNS drive
to be updated and use generic method to calculate number of zones
instead of relying on log and shift based calculation on zone size.
The power_of_2 calculation has been replaced directly with generic
calculation without special handling. Both modified functions are not
used in hot paths, they are only used during initialization &
revalidation of the ZNS device.
Reviewed-by: Luis Chamberlain <mcgrof@xxxxxxxxxx>
Signed-off-by: Pankaj Raghav <p.raghav@xxxxxxxxxxx>
---
drivers/nvme/host/zns.c | 11 ++---------
1 file changed, 2 insertions(+), 9 deletions(-)
diff --git a/drivers/nvme/host/zns.c b/drivers/nvme/host/zns.c
index 9f81beb4df4e..2087de0768ee 100644
--- a/drivers/nvme/host/zns.c
+++ b/drivers/nvme/host/zns.c
@@ -101,13 +101,6 @@ int nvme_update_zone_info(struct nvme_ns *ns, unsigned lbaf)
}
ns->zsze = nvme_lba_to_sect(ns, le64_to_cpu(id->lbafe[lbaf].zsze));
- if (!is_power_of_2(ns->zsze)) {
- dev_warn(ns->ctrl->device,
- "invalid zone size:%llu for namespace:%u\n",
- ns->zsze, ns->head->ns_id);
- status = -ENODEV;
- goto free_data;
- }
blk_queue_set_zoned(ns->disk, BLK_ZONED_HM);
blk_queue_flag_set(QUEUE_FLAG_ZONE_RESETALL, q);
@@ -129,7 +122,7 @@ static void *nvme_zns_alloc_report_buffer(struct nvme_ns *ns,
sizeof(struct nvme_zone_descriptor);
nr_zones = min_t(unsigned int, nr_zones,
- get_capacity(ns->disk) >> ilog2(ns->zsze));
+ div64_u64(get_capacity(ns->disk), ns->zsze));
Same here; please add a helper calculating the number of zones for a
given disk.
bufsize = sizeof(struct nvme_zone_report) +
nr_zones * sizeof(struct nvme_zone_descriptor);
@@ -197,7 +190,7 @@ int nvme_ns_report_zones(struct nvme_ns *ns, sector_t sector,
c.zmr.zrasf = NVME_ZRASF_ZONE_REPORT_ALL;
c.zmr.pr = NVME_REPORT_ZONE_PARTIAL;
- sector &= ~(ns->zsze - 1);
+ sector = rounddown(sector, ns->zsze);
while (zone_idx < nr_zones && sector < get_capacity(ns->disk)) {
memset(report, 0, buflen);
Please be a bit more consistent. In the previous patches you always had
a condition to check if it's a power_of_2 zone size, but here you are
using the same calculation for each disk.
So please use the check in all locations, or add a comment why the
generic calculation is okay to use here.
Cheers,
Hannes
--
Dr. Hannes Reinecke Kernel Storage Architect
hare@xxxxxxx +49 911 74053 688
SUSE Software Solutions GmbH, Maxfeldstr. 5, 90409 Nürnberg
HRB 36809 (AG Nürnberg), Geschäftsführer: Felix Imendörffer