Re: [PATCH 3/5] dt-bindings: iio: correct node names in examples

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 21/01/2023 18:17, Jonathan Cameron wrote:
> On Wed, 18 Jan 2023 19:44:11 +0100
> Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxx> wrote:
> 
>> Do not use underscores and unneeded suffixes (e.g. i2c0) in node name in
>> examples.
>>
>> Signed-off-by: Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxx>
>> ---
> 
>> diff --git a/Documentation/devicetree/bindings/iio/health/ti,afe4403.yaml b/Documentation/devicetree/bindings/iio/health/ti,afe4403.yaml
>> index 6c5ad426a016..12f75ddc4a70 100644
>> --- a/Documentation/devicetree/bindings/iio/health/ti,afe4403.yaml
>> +++ b/Documentation/devicetree/bindings/iio/health/ti,afe4403.yaml
>> @@ -42,7 +42,7 @@ examples:
>>          #address-cells = <1>;
>>          #size-cells = <0>;
>>  
>> -        heart_mon@0 {
>> +        heart-rate@0 {
> 
> These are both heart-rate and pulse oximeters so measure more than just
> the rate (oxygen saturation in the blood). Reality is they actually
> measure light absorption over time, but you can calculate an estimate
> of both rate and oxygen saturation from that.
> 
> I don't really mind simplifying that to heart-rate, but wanted to
> call this out for possible discussion.

They could be heart-mon. The fix is mostly around the underscore. I
don't have any arguments for changing it to heart-rate, thus we can go
with whatever you prefer.

Best regards,
Krzysztof