(14/09/16 (火) 22:31), Vlad Yasevich wrote: > On 09/16/2014 07:28 AM, Toshiaki Makita wrote: >> On 2014/09/16 0:19, Vlad Yasevich wrote: >>> On 09/14/2014 11:39 AM, Toshiaki Makita wrote: >>>> (14/09/13 (土) 5:44), Vladislav Yasevich wrote: >>>>> If the user configures vlan devices on top of the bridge, >>>>> automatically set up filter entries for it as long as >>>>> bridge vlan protocol matches that of the vlan. >>>>> This allows the user to atomatically receive vlan traffic >>>>> for the vlans that are convifgured. >>>> >>>> Changing br->vlan_proto seems to cause inconsistency between vlan >>>> interfaces and filter settings. >>>> Can we automatically change filters when setting vlan_proto? >>>> >>> >>> I thought we already do that in br_vlan_set_proto()? Nothing >>> here introduces any new kinds of issue with that code. >> >> I'm referring to a case like this: >> 1. create br0.10 (802.1ad) >> 2. change br->vlan_proto into 88a8 >> >> When creating br0.10 (1), br->vlan_proto is 8100 and different from >> protocol of br0.10, so it is ignored by br_vlan_rx_add_vid(). >> After changing br->vlan_proto (2), we might expect vlan 10 is not >> filtered on br0, but it will be filtered. > > Ok, I see what you mean. This one is a bit tough. Our options are: > 1) Return an error when configuring br0.10. This might break user-space. Not good. > 2) Ignore protocol when crating the filter. This is not good either as the user > may not switch the bridge vlan_proto value and we'd end up with a wrong filter. > 3) Re-implement .1ad support per-vlan instead of per-bridge. > > You see another other alternatives? We might be able to configure filterings on changing vlan_proto. 4) Memorize different protocol's filtering requests in br_vlan_rx_add_vid() and use them when switching vlan_proto. 5) Scan vlan devices on bridge device when changing vlan_proto. Thanks, Toshiaki Makita