From: Oleg Drokin <green@xxxxxxxxxxxxxx> This patch fixes "Block comments use a trailing */ on a separate line" warnings from checkpatch Signed-off-by: Oleg Drokin <green@xxxxxxxxxxxxxx> --- drivers/staging/lustre/lustre/mgc/mgc_request.c | 71 ++++++++++++++++--------- 1 file changed, 46 insertions(+), 25 deletions(-) diff --git a/drivers/staging/lustre/lustre/mgc/mgc_request.c b/drivers/staging/lustre/lustre/mgc/mgc_request.c index 9764e57..6fc8225 100644 --- a/drivers/staging/lustre/lustre/mgc/mgc_request.c +++ b/drivers/staging/lustre/lustre/mgc/mgc_request.c @@ -90,7 +90,8 @@ static int mgc_name2resid(char *name, int len, struct ldlm_res_id *res_id, int mgc_fsname2resid(char *fsname, struct ldlm_res_id *res_id, int type) { /* fsname is at most 8 chars long, maybe contain "-". - * e.g. "lustre", "SUN-000" */ + * e.g. "lustre", "SUN-000" + */ return mgc_name2resid(fsname, strlen(fsname), res_id, type); } EXPORT_SYMBOL(mgc_fsname2resid); @@ -102,7 +103,8 @@ static int mgc_logname2resid(char *logname, struct ldlm_res_id *res_id, int type /* logname consists of "fsname-nodetype". * e.g. "lustre-MDT0001", "SUN-000-client" - * there is an exception: llog "params" */ + * there is an exception: llog "params" + */ name_end = strrchr(logname, '-'); if (!name_end) len = strlen(logname); @@ -125,7 +127,8 @@ static int config_log_get(struct config_llog_data *cld) } /* Drop a reference to a config log. When no longer referenced, - we can free the config log data */ + * we can free the config log data + */ static void config_log_put(struct config_llog_data *cld) { CDEBUG(D_INFO, "log %s refs %d\n", cld->cld_logname, @@ -252,7 +255,8 @@ static struct config_llog_data *config_recover_log_add(struct obd_device *obd, char logname[32]; /* we have to use different llog for clients and mdts for cmd - * where only clients are notified if one of cmd server restarts */ + * where only clients are notified if one of cmd server restarts + */ LASSERT(strlen(fsname) < sizeof(logname) / 2); strcpy(logname, fsname); LASSERT(lcfg.cfg_instance); @@ -483,8 +487,9 @@ static void do_requeue(struct config_llog_data *cld) LASSERT(atomic_read(&cld->cld_refcount) > 0); /* Do not run mgc_process_log on a disconnected export or an - export which is being disconnected. Take the client - semaphore to make the check non-racy. */ + * export which is being disconnected. Take the client + * semaphore to make the check non-racy. + */ down_read(&cld->cld_mgcexp->exp_obd->u.cli.cl_sem); if (cld->cld_mgcexp->exp_obd->u.cli.cl_conn_count != 0) { CDEBUG(D_MGC, "updating log %s\n", cld->cld_logname); @@ -529,8 +534,9 @@ static int mgc_requeue_thread(void *data) } /* Always wait a few seconds to allow the server who - caused the lock revocation to finish its setup, plus some - random so everyone doesn't try to reconnect at once. */ + * caused the lock revocation to finish its setup, plus some + * random so everyone doesn't try to reconnect at once. + */ to = MGC_TIMEOUT_MIN_SECONDS * HZ; to += rand * HZ / 100; /* rand is centi-seconds */ lwi = LWI_TIMEOUT(to, NULL, NULL); @@ -559,7 +565,8 @@ static int mgc_requeue_thread(void *data) LASSERT(atomic_read(&cld->cld_refcount) > 0); /* Whether we enqueued again or not in mgc_process_log, - * we're done with the ref from the old enqueue */ + * we're done with the ref from the old enqueue + */ if (cld_prev) config_log_put(cld_prev); cld_prev = cld; @@ -575,7 +582,8 @@ static int mgc_requeue_thread(void *data) config_log_put(cld_prev); /* break after scanning the list so that we can drop - * refcount to losing lock clds */ + * refcount to losing lock clds + */ if (unlikely(stopped)) { spin_lock(&config_list_lock); break; @@ -598,7 +606,8 @@ static int mgc_requeue_thread(void *data) } /* Add a cld to the list to requeue. Start the requeue thread if needed. - We are responsible for dropping the config log reference from here on out. */ + * We are responsible for dropping the config log reference from here on out. + */ static void mgc_requeue_add(struct config_llog_data *cld) { CDEBUG(D_INFO, "log %s: requeue (r=%d sp=%d st=%x)\n", @@ -635,7 +644,8 @@ static int mgc_llog_init(const struct lu_env *env, struct obd_device *obd) int rc; /* setup only remote ctxt, the local disk context is switched per each - * filesystem during mgc_fs_setup() */ + * filesystem during mgc_fs_setup() + */ rc = llog_setup(env, obd, &obd->obd_olg, LLOG_CONFIG_REPL_CTXT, obd, &llog_client_ops); if (rc) @@ -697,7 +707,8 @@ static int mgc_precleanup(struct obd_device *obd, enum obd_cleanup_stage stage) static int mgc_cleanup(struct obd_device *obd) { /* COMPAT_146 - old config logs may have added profiles we don't - know about */ + * know about + */ if (obd->obd_type->typ_refcnt <= 1) /* Only for the last mgc */ class_del_profiles(); @@ -794,7 +805,8 @@ static int mgc_blocking_ast(struct ldlm_lock *lock, struct ldlm_lock_desc *desc, break; } /* Make sure not to re-enqueue when the mgc is stopping - (we get called from client_disconnect_export) */ + * (we get called from client_disconnect_export) + */ if (!lock->l_conn_export || !lock->l_conn_export->exp_obd->u.cli.cl_conn_count) { CDEBUG(D_MGC, "log %.8s: disconnecting, won't requeue\n", @@ -816,7 +828,8 @@ static int mgc_blocking_ast(struct ldlm_lock *lock, struct ldlm_lock_desc *desc, /* Not sure where this should go... */ /* This is the timeout value for MGS_CONNECT request plus a ping interval, such - * that we can have a chance to try the secondary MGS if any. */ + * that we can have a chance to try the secondary MGS if any. + */ #define MGC_ENQUEUE_LIMIT (INITIAL_CONNECT_TIMEOUT + (AT_OFF ? 0 : at_min) \ + PING_INTERVAL) #define MGC_TARGET_REG_LIMIT 10 @@ -880,7 +893,8 @@ static int mgc_enqueue(struct obd_export *exp, struct lov_stripe_md *lsm, cld->cld_resid.name[0]); /* We need a callback for every lockholder, so don't try to - ldlm_lock_match (see rev 1.1.2.11.2.47) */ + * ldlm_lock_match (see rev 1.1.2.11.2.47) + */ req = ptlrpc_request_alloc_pack(class_exp2cliimp(exp), &RQF_LDLM_ENQUEUE, LUSTRE_DLM_VERSION, LDLM_ENQUEUE); @@ -895,7 +909,8 @@ static int mgc_enqueue(struct obd_export *exp, struct lov_stripe_md *lsm, rc = ldlm_cli_enqueue(exp, &req, &einfo, &cld->cld_resid, NULL, flags, NULL, 0, LVB_T_NONE, lockh, 0); /* A failed enqueue should still call the mgc_blocking_ast, - where it will be requeued if needed ("grant failed"). */ + * where it will be requeued if needed ("grant failed"). + */ ptlrpc_req_finished(req); return rc; } @@ -1373,7 +1388,8 @@ again: } /* always update the index even though it might have errors with - * handling the recover logs */ + * handling the recover logs + */ cfg->cfg_last_idx = res->mcr_offset; eof = res->mcr_offset == res->mcr_size; @@ -1400,7 +1416,8 @@ again: mne_swab = !!ptlrpc_rep_need_swab(req); #if LUSTRE_VERSION_CODE < OBD_OCD_VERSION(3, 2, 50, 0) /* This import flag means the server did an extra swab of IR MNE - * records (fixed in LU-1252), reverse it here if needed. LU-1644 */ + * records (fixed in LU-1252), reverse it here if needed. LU-1644 + */ if (unlikely(req->rq_import->imp_need_mne_swab)) mne_swab = !mne_swab; #else @@ -1489,7 +1506,8 @@ static int mgc_process_cfg_log(struct obd_device *mgc, /* logname and instance info should be the same, so use our * copy of the instance for the update. The cfg_last_idx will - * be updated here. */ + * be updated here. + */ rc = class_config_parse_llog(env, ctxt, cld->cld_logname, &cld->cld_cfg); @@ -1529,9 +1547,10 @@ int mgc_process_log(struct obd_device *mgc, struct config_llog_data *cld) LASSERT(cld); /* I don't want multiple processes running process_log at once -- - sounds like badness. It actually might be fine, as long as - we're not trying to update from the same log - simultaneously (in which case we should use a per-log sem.) */ + * sounds like badness. It actually might be fine, as long as + * we're not trying to update from the same log + * simultaneously (in which case we should use a per-log sem.) + */ mutex_lock(&cld->cld_lock); if (cld->cld_stopping) { mutex_unlock(&cld->cld_lock); @@ -1556,7 +1575,8 @@ int mgc_process_log(struct obd_device *mgc, struct config_llog_data *cld) CDEBUG(D_MGC, "Can't get cfg lock: %d\n", rcl); /* mark cld_lostlock so that it will requeue - * after MGC becomes available. */ + * after MGC becomes available. + */ cld->cld_lostlock = 1; /* Get extra reference, it will be put in requeue thread */ config_log_get(cld); @@ -1642,7 +1662,8 @@ static int mgc_process_config(struct obd_device *obd, u32 len, void *buf) /* COMPAT_146 */ /* FIXME only set this for old logs! Right now this forces - us to always skip the "inside markers" check */ + * us to always skip the "inside markers" check + */ cld->cld_cfg.cfg_flags |= CFG_F_COMPAT146; rc = mgc_process_log(obd, cld); -- 2.1.0 _______________________________________________ devel mailing list devel@xxxxxxxxxxxxxxxxxxxxxx http://driverdev.linuxdriverproject.org/mailman/listinfo/driverdev-devel