[RFC PATCH 5/7] iio:ABI docs: Combine sysfs-bus-iio-humidity-hdc2010/hdc100x into one file

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



From: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx>

These contain only one entry for out_current_heater_raw (_available).
Document this in a new sysfs-bus-iio-humidity file, and make it a little
more generic by allowing for non 0/1 values.

Fixes:
$ scripts/get_abi.pl validate
Warning: /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw is defined 2 times:  ./Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010:0  ./Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x:0
Warning: /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw_available is defined 2 times:  ./Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010:1  ./Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x:1

Cc: Eugene Zaikonnikov <ez@xxxxxxxxxxxxx>
Cc: Matt Ranostay <matt.ranostay@xxxxxxxxxxxx>
Reported-by: Mauro Carvalho Chehab <mchehab+huawei@xxxxxxxxxx>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx>
---
 ...s-bus-iio-humidity-hdc2010 => sysfs-bus-iio-humidity} | 3 ++-
 Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x | 9 ---------
 2 files changed, 2 insertions(+), 10 deletions(-)

diff --git a/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010 b/Documentation/ABI/testing/sysfs-bus-iio-humidity
similarity index 79%
rename from Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010
rename to Documentation/ABI/testing/sysfs-bus-iio-humidity
index 5b78af5f341d..cb0d7e75d297 100644
--- a/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010
+++ b/Documentation/ABI/testing/sysfs-bus-iio-humidity
@@ -6,4 +6,5 @@ Description:
 		Controls the heater device within the humidity sensor to get
 		rid of excess condensation.
 
-		Valid control values are 0 = OFF, and 1 = ON.
+		In some devices, this is just a switch in which case 0 = OFF,
+		and 1 = ON.
diff --git a/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x b/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x
deleted file mode 100644
index b72bb62552cf..000000000000
--- a/Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x
+++ /dev/null
@@ -1,9 +0,0 @@
-What:		/sys/bus/iio/devices/iio:deviceX/out_current_heater_raw
-What:		/sys/bus/iio/devices/iio:deviceX/out_current_heater_raw_available
-KernelVersion:	4.3
-Contact:	linux-iio@xxxxxxxxxxxxxxx
-Description:
-		Controls the heater device within the humidity sensor to get
-		rid of excess condensation.
-
-		Valid control values are 0 = OFF, and 1 = ON.
-- 
2.30.0