Hi Milton,
Thanks for sharing your time to review this patch. Please see my answer
inline.
Jae
On 3/9/2018 3:41 PM, Milton Miller II wrote:
About 03/07/2018 04:12PM in some time zone, Pavel Machek wrote:
Subject: Re: [PATCH v2 2/8] [PATCH 2/8] Documentations: dt-bindings:
Add a document of PECI adapter driver for Aspeed AST24xx/25xx SoCs
Hi!
Are these SoCs x86-based?
Yes, these are ARM SoCs. Please see Andrew's answer as well.
Understood, thanks.
+ Read sampling point selection. The whole period of a bit time
will be
+ divided into 16 time frames. This value will determine which
time frame
+ this controller will sample PECI signal for data read back.
Usually in
+ the middle of a bit time is the best.
English? "This value will determine when this controller"?
Could I change it like below?:
"This value will determine in which time frame this controller
samples PECI
signal for data read back"
I guess... I'm not native speaker, I guess this could be improved
some
more.
I agree this wording is still confusing.
The problem is that the key subject, the time of the sampling, is in the descriptive clause "in which time frame".
"This value will determine the time frame in which the controller will sample"
or perhaps phrase it as saving a specific sample from the over-clock, or a phase of the clock.
Yes, that looks more better. I'll change the wording as you suggested.
Thanks a lot!
Jae
Best regards,
Pavel
--
(english) http://www.livejournal.com/~pavelmachek
(cesky, pictures)
http://atrey.karlin.mff.cuni.cz/~pavel/picture/horses/blog.html
milton
--
Speaking for myself not IBM.
--
To unsubscribe from this list: send the line "unsubscribe linux-doc" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html